  • Easily remove entire tiles with the NovaStrip 378 infrared radiant heat floor stripper.
  • It uses safe 110v-20Amp current to heat the bonding agents that attach the tile and enables intact, dustless removal.
  • Compact design allows easy access to tight spaces

The NovaStrip 378 utilizes "Infrared Radiant Heat" at 110volts to safely heat tiles, thus breaking the adhesive bond. This allows you to lift "INTACT" tiles in a dustless environment. The NovaStrip 378 features individual ceramic emitter strips that are fully replaceable. No need to replace the entire heat panel.

To use, simply plug the unit into any 20Amp, 110volt grounded outlet, place the machine over the tiles to be removed, allow it to complete its heating cycle, and then easily remove the tiles.

Features and Benefits

  • Mid Range 378 square inch footprint removes 2-12”x 12” in one cycle
  • Operates on a 110V or 220V current
  • Identical controls to the N1026
  • Compact design allows easy access to tight spaces
  • Heavy duty and light-weight aluminum construction

Specifications

  • Part no.: N378
  • Weight: 45lbs.
  • Height:  46"
  • Tile Removal: 9”x9”=3 & 12”x12”=2
  • Power Requirements: 110 volts, 15amp.
  • Pad Size: 14” x 28”
More Information
Brand Novatek
Hand Tool Type Floor Stripper
Voltage 110V
Current 20 Amp
Material Aluminum

Prior to Start-up:

Prior to attempting tile removal with the Novastrip ensure the following:

  1. Make sure to clean dirt and debris from floor surface prior to tile removal.
  2. Whenever possible, strip excess wax and/or coating build-up on floor surface.
  3. Familiarize yourself with all fire extinguishers, fire safety equipment, and emergency exits.
  4. Remove any dust, dirt, or waxy residue build-up on heat panel surface.
  5. Remove any dust or dirt built-up on the controls and control panel.
  6. Make sure you have heat resistant gloves for the HOT tile removal.
  7. You might have to install the handle if the unit was shipped to your location. When installing the handle, make sure
    to connect the power plug and thermocouple.

Start-up:

  1. Position unit over a section of concrete to allow unit to heat to desired temperature. If concrete area is unavailable position unit over tile being removed.
  2. Check unit to make sure emergency stop button, breaker and key switch are in the off position.
  3. Plug power cord into unit and be sure to twist cord connector ¼ turn clockwise to lock the plug into position.
  4. Plug power cord into a grounded 20Amp outlet for N378.
  5. Pull emergency stop button out to the ON position.
  6. The temperature / timer controller will light and run a self-diagnosis test which will take about five (5) seconds. If not, make sure Emergency STOP Button is in the pulled-out position and there is grounded power going to the unit.
  7. Heat panel will take about 15-20 minutes to heat to the factory preset temperature. CAUTION: At this point unit is on and panel is heating. 
    If the Novastrip is positioned over tile, check tile periodically to ensure you are not over-heating the area. Unit may
    have to be moved to a new section of tile before unit is up to full temperature.  CAUTION: While heat panel is heating to temperature if positioned over tile, check the tile periodically to insure you are not over heating the tile area. Unit may have to be moved to a new section of tile before unit is up to full temperature.
  8. Once the unit reaches full temperature, reset timer to begin the timing function. This timer may be reset to meet your needs with a maximum preset time of 59.99.

NOTE: Once the timer reaches ZERO, power is cut to the heat panel, push the reset button to start elapse time or unit will proceed to cool down.

Removal Procedure

At this point the heat panel has heated to full temperature ready for heat application. Different floor characteristics such as the tile thickness, tile adhesive, or just the material makeup of the tile will result in different heat-up and removal times. A routine will quickly be established for each new removal application.

  1. Place NOVASTRIP 378 over designated area of tile to be removed.
  2. Push the timer reset button to start / continue the preset time cycle.
  3. Once the timer reaches zero an audible alarm will sound. This means it is time to move the unit to a new section of tile to be removed. Press reset button.
  4. While the unit is heating the new section of tile, remove the previously heated tile with a Long Reach Scraper.
  5. Once you have completed your removal application for the day, allow the time cycle to reach zero (alarm will sound) or press Emergency Stop Button.
  6. This will shut off the power to the heat panel and the controller will go into cool down mode which will allow it to return to room temperature.
  7. Place a block under the front of the unit’s base shroud. This will allow air to circulate under the shroud helping to accelerate the cooling process.
  8. The controller display will indicate the cooling process.
  9. Once the controller displays "safe to transport" and the heat panel sticker on top of base shows 95° or less, the unit is ready to be moved.
  10. Disconnect plug from power source.