Dri-Eaz F479 HVE 3000 Portable Flood Pumper

Rating:
100 % of 100
$4,194.00
In stock
Only 2 left
SKU
WE3000

High vacuum and powerful lift pull maximum water from carpet and pad fast while a clog-resistant, high-volume industrial pump delivers up to 50 GPM. A narrow profile and large rear wheels make transport easy. The unit can also be used with a truck mount to boost the vacuum or intercept extracted water to keep the truck mount tank from filling up.

High vacuum and powerful lift pulls maximum water from carpet and pad fast while a clog-resistant, high-volume industrial pump delivers up to 50 gpm. A narrow profile and large rear wheels make transport easy. The unit can also be used with a truckmount to boost vacuum or intercept extracted water to keep truck mount tank from filling up.

Features

  • Clear-view first-stage filter lifts out for easy rinsing.
  • A high flow, high volume clog-resistant sump pump handles up to ½ in. solids.
  • Rugged construction.
  • Low center of gravity provides balanced transport; easy on stairs!
  • Use the HVE 3000 to bypass the truckmount waste tank for black water flood extraction to keep the tank clean.
  • Accessories included One 25 ft. section of 2 in. vacuum hose with cuffs
  • Dual vacuum blowers with 2 in. inlet ensures maximum airflow.
  • Easy maneuverability – just pull on the hose!
  • Slim profile to fit through the narrowest doors – only 22.5 in. wide.
  • Large capacity waste tank.
  • 12 gallon tank means fewer trips to the drain when you're not using the auto-pumpout system.
  • Two auto-pumpout options: barbed outlet for a 1½ in. drain hose and a ¾ in. converter outlet fitting for use with a standard garden hose.
  • Use the large toilet-height gravity drain for small jobs and easy tank cleanout.
  • Exhaust air passes through HEPA filter. Helps to prevent the spread of contaminants and odors and conforms to 2015 IICRC S500 (13.3.3) recommendations.

Specifications

  • Static pressure (Blower 1):  8 in. Hg | 108 in.
  • H2O Static pressure (Blower 2):  10 in. Hg | 136 in. H2O
  • Static Pressure (Both blowers):  12 in. Hg | 164 in.
  • H2O Pumpout discharge rates:  50 gpm (1.5 in. outlet); 12 gpm (0.75 in. outlet)
  • Dimensions (W × H × D):  22.5 × 40.2 × 23.6 in. | 57.2 × 102.1 × 59.9 cm
  • Weight:  132 lbs. | 60 kg
  • Volts:  115V Amps:  12A (Blower 1 + Pumpout) 13.5A (+Blower 2)
  • Frequency:  60Hz
  • Tank capacity:  12 gal. | 45L Power:  115V
  • Safety:  ETL listed to UL/cUL and CSA standards. Xactimate:  WTR EXT (+ & W)
More Information
Brand Dri-Eaz
Type Flood Pumper
Color Blue
Usage Cleaning Tool
Dimensions 22.5 × 40.2 × 23.6 inch
Voltage 115V
Power 12A (Blower 1 + Pumpout) 13.5A (+Blower 2)
Pumpout Discharge Rates 50 gpm (1.5 in. outlet); 12 gpm (0.75 in. outlet)
Tank Capacity 12 gallons
Safety Certification ETL listed to UL/cUL and CSA standards
Frequency 60hz
Write Your Own Review
Write a ReviewDri-Eaz F479 HVE 3000 Portable Flood Pumper

Extraction Mode Setup

Remove water quickly and effectively from flooded structures.

  1. Remove the HEPA filter when performing Category 1 or 2 restoration jobs. The HEPA filter is intended for use only with Category 3 jobs.
  2. Connect vacuum hose to vacuum inlet.
  3. Connect one or two power cords depending on job requirements. The second cord must be connected to a separate 15 amp circuit.

NOTICE: The power cords of the HVE3000 should be  plugged into separate GFCI-protected 115 volt outlets rated for at least 15 amps. Always plug the cord firmly into the base of the unit first and secure the cord into the cord clip.
NOTICE: Connect to two separate 15A circuits ONLY. A  bright green light indicates correct connections. No light will show when using only one cord.

For automatic pumpout, connect hose to pumpout outlet to pump outlet and turn pump switch ON. Do not use anything smaller than a ⅝ in. hose, and ensure there are no kinks in the hose. For increased pumpout performance, see “Maximizing Pumpout Performance,”.

NOTICE: Before turning the pump on, attach a drain hose and place the end in an approved drain. Check with local authorities for proper wastewater disposal. Operating the pump without a drain hose in place may cause injury.

NOTICE: Avoid contact with water draining from the pump outlet. Water is pressurized and may exit the unit with force. Water may contain chemicals or contaminants that can be a health hazard upon contact.

4) Turn on vacuum pump(s) to LOW, MED or HIGH. The machine can operate with either one or both vacuum pumps running. For maximum vacuum performance, turn on both Vacuum Pump 1 and Vacuum Pump 2.

Truckmount Booster Setup

Use in conjunction with a truckmount extractor to provide additional extraction power. The HVE3000 has been tested to boost vacuum on hose runs as long as 300 ft. (90 m). To maximize performance, we recommend using the shortest runs as possible.

NOTICE: Do not attempt to operate the unit with a truckmount producing vacuum pressures greater than 12 in. Hg (164 in. H20). Doing so could damage the unit and will void the warranty. NOTICE: Do not operate with water temperatures exceeding 140° F (60° C). Doing so could damage the unit and will void the warranty.

1) Connect vacuum hose to vacuum inlet.
2) Connect one or two power cords depending on job requirements. The second cord must be connected to a separate 15 amp circuit. A green light indicates the unit has been correctly connected to separate circuits.

WARNING: The power cords of the HVE3000 should be plugged into separate GFCI-protected 115 volt outlets rated for at least 15 amps. Always plug the cord firmly into the base of the unit first and secure the cord into the cord clip.

NOTICE: Connect to two separate 15A circuits ONLY. A bright green light indicates correct connections. No light will show when using only one cord.

3) Connect pumpout hose to pump outlet and turn pump switch ON. For maximum pumpout performance, we recommend using the unit with a 1½ in outlet hose.

4) Attach vacuum hose to truckmount via vacuum outlet.

5) Turn on vacuum pump(s) to LOW, MED or HIGH. The machine can operate with either one or both vacuum pumps running. For maximum vacuum pressure, turn on both Vacuum Pump 1 and Vacuum Pump 2.

Maximizing pumpout performance

The sump pump outlet of HVE3000 is equipped with a 1½ in. barbed hose fitting for use with a 1½ in. drain hose (hose purchased separately). Because the internal pumpout system is plumbed with 1½ in. lines, use of a large-diameter drain hose will help to ensure maximum pumpout performance.

The HVE3000 may also be used with a standard garden hose. Simply replace the 1½ in. fitting with the ¾ in. reducer fitting supplied with your unit and attach the garden hose.

Attachments