Portable, high-performance water removal—even at low humidity levels. Reduce and control excess moisture fast with the unit’s patented cross-flow technology that optimizes moisture removal in virtually all conditions. Features the new Command Hub, compatible with the new Command Center App. Available in early 2023 in the Apple Store and Google Play Store.
Features
- NEW! Command Hub touchscreen controller displays real-time temp, RH, grain depression and drying progress trends at a glance. Controller integration product for existing i-Series dehumidifiers also available.
- Advanced Crossflow Technology maximizes efficiency and ensures superior performance in low-grain conditions.
- Fast and convenient access to humidistat, job hours, maintenance reminders and more.
- Process outlet fits 12 in. layflat and rigid ducting.
- Sealed large-capacity pump basin – large enough to contain water from an unintentional defrost after a power outage or other unexpected shut-down.
- Ergonomic design. Handle 2 in. taller for easier use on stairs, folds down for storage. Integrated cord and hose storage.
- Legendary rotomolded housing – practically indestructible – stackable for storage to save space.
- Automatic restart after outage when power is restored.
Specifications
- Water removal AHAM (80°F/60%RH): 130 pts. | 61.5 L / day
- Max. water removal (saturation): 235 pts. | 111 L / day
- Process air (max.): 325 CFM | 552 CMH. Floor-level outlet.
- Dimensions (W × H × D): 20 × 33.5 × 20 in. | 51 × 85 × 51 cm
- Use weight: 107 lbs. | 49 kg
- Amps: 8.3A
- Volts: 115V
- Frequency: 60Hz
- Power cord: 25 ft. | 7.6 m
- Drain hose: 40 ft. | 12.2 m
- Filter type: 4-PRO filter
- Operating range: 33°F–100°F | 1°C–38°C
- Housing: Rotomolded polyethylene
- Safety: ETL listed to CSA 22.2 no. 92
- Xactimate: WTRDHM>>XL
Accessories
- 4-PRO Four-Stage Air Filter
- Sto and Go Vortex Ducting
Brand | Dri-Eaz |
---|---|
Dimensions | 20 × 33.5 × 20 in |
Air Filtration Tool Type | Dehumidifier |
Water Removal AHAM | 61.5 L / day |
Max. Water Removal | 111 L / day |
CFM | 325 CFM (max) |
Current | 8.3 Amp |
Voltage | 115V |
Frequency | 60hz |
Construction | Rotomolded polyethylene |
Cord Length | 25 Feet |
Filtration | 4-PRO filter |
Write Your Own Review
The Legend Brands® LGR 7000XLi dehumidifier reduces humidity in enclosed environments by removing water vapor from the air. The 7000XLi is rugged, durable and highly portable, making it ideal for water damage restoration, structural drying, construction, and other applications requiring temporary, high-performance dehumidification.
- Inspect the power cord before use. If cord is damaged, do not use. Always grasp the plug (not the cord) to unplug.
- Insert three-prong plug on power cord into a matching electrically grounded outlet. Do not use adapter. Never cut off third prong. Do not use an extension cord.
- The unit must be operated on a 120V/60Hz circuit protected by a Ground Fault Circuit Interrupter (GFCI) device.
- Keep motor and wiring dry.
- Do not attempt to repair the unit
LGR (low-grain refrigerant) dehumidifiers utilize an internal pre-cooling system to boost water removal efficiency. LGR units can continue to remove moisture in drier environments where conventional refrigerants cannot.
Operating Your Dehumidifier
Set unit upright
NOTICE: Transporting or storing the unit in a horizontal position is not recommended. When the machine is placed in a horizontal position, the oil from the compressor can flow into the refrigerant coils and reduce the ability of the dehumidifier to function and possibly damage the unit. If the unit has been placed in a horizontal position, set it upright and let it stand for at least 30 minutes before turning it on.
Positioning a Dehumidifier
For best results, operate your dehumidifiers in an enclosed area. Close all doors and windows that open to the outside to maximize the unit’s water
removal efficiency. Place your dehumidifier away from obstructions, and keep it away from anything that could block airflow into and out of the unit.
Set up drain hose
This unit automatically pumps out water on a regular basis. The condensate pump connects to a plastic drainage hose that is located in the pocket on the side of the unit. This hose is equipped with a quick-connect fitting for quick attachment to the provided drain hose. Unwrap the entire hose and place the unattached end in a sink, drain, bucket or outdoors – anywhere that water can drain out safely. If you use a bucket or other container for water collection, check it regularly to prevent overflows.
NOTICE: Uncoil and straighten the entire drain hose. Do not leave any part of the hose coiled on the unit and do not place the end of the hose higher than 20 ft. (6 m) above the bottom of the unit. Also check for kinks or other obstructions that might restrict the flow of water. Obstructions may cause a water backup and result in overflows.
Plug in electrical cord
The dehumidifier should be plugged into a GFCI protected 120 volt outlet rated for at least 15 amps. Remove the cord from its storage pocket and uncoil it.
Always plug the cord firmly into the unit first, and then plug the other end into a suitable outlet.
Turn the unit on
The control panel has a display and a touchpad with four keys. Press the ON/OFF to turn the unit on. The unit will now go through a compressor delay countdown (up to 60 seconds in duration) and a self-diagnostics process, then switch to normal display mode.
Startup display and normal display modes
When unit is first plugged in to AC power, the control panel display will briefly cycle through a series of readouts. This is part of the unit’s self-diagnosis
procedure and no user intervention is required.
More from Dri-Eaz
We found other products you might like!