Give Us A Call: (800) 872-3684

Gilian GilAir-5 Air Sampling Pump 5 Pack Kit

$5,110.67
In stock
SKU
AS0170
The Sensidyne Gilian GilAir-5 Constant Flow Sampling Pump provides industrial hygienists and safety managers with a dynamic air sampling system operating at a flow rate of 1-5000 cc/min.

What's Included

Includes: Five GilAir-5 Pumps, Five pieces of 36” Tubing, Five Air Boss Kits, Five Filter Cassette Holders, Five Reversible Screwdrivers, Five User Manuals and a 5-Unit Charger or BMS-II (NiCad only).
 

Key Features

The Sensidyne Gilian GilAir-5 Constant Flow Sampling Pump provides industrial hygienists and safety managers with a dynamic air sampling system operating at a flow rate of 1-5000 cc/min.

  • Basic, Clock, & Programmable Models
  • The GilAir-5 is available in 3 models; Basic, Clock and Programmable. The Basic model is straight-forward and easy to use. Clock models provide an elapsed-time clock display. Programmable models enable a timer which can start or stop the Gilian pump at preset time intervals or program a delayed start.
  • Automatic constant flow
  • The most important feature of any sampling pump is standard on all GilAir-3 and GilAir-5 pumps. It assures flow is maintained within 5% of the initial set point, even with varying back-pressures from flow restrictions or buildup of material on the filter. GilAir-3 and GilAir-5 pumps are suitable not only for conventional pull-through sampling media but also for bag sampling and other pressure applications.
  • Flow Fault & Test Indicators
  • The fault light indicator activates when the pump flow control is outside +/-5% of the required flow rate, such as from low battery, blocked tubing or filter. If fault conditions persist for 30-60 seconds, the pump automatically shuts down and freezes the timer. Models with a timer display preserve run time on the display, ensuring a valid sampling result. When the fault condition is cleared before shutdown, the pump will resume normal sampling and fault light turns off. The GilAir-5 also has a Battery Test indicator light that illuminates when the battery can provide a minimum of 8 hours of operation over operating range.
  • External Filter Housing
  • Clear filter housing allows an immediate visual inspection of the internal filter's condition. This feature protects the pump from dirt and debris and is externally mounted on the pump, allowing for quick inspection. Filter replacement requires the removal of just four screws. A built-in moisture trap helps prevent moisture from entering and damaging the pump chamber, such as moisture carryover from impingers.
  • Optional Low Flow Modules
  • Constant Flow module allows sampling from 20-500 cc/min.
  • Constant Pressure (Multi-flow) Module allows sampling from 1-750 cc/min.
  • These modules can be quickly added to pumps to adapt them to the lower flow rates required for sorbent tube sampling. The multi-flow module maintains constant pressure and allows sampling with multiple sorbent tubes, each with an independently set flow rate.

This comprehensive 3-in-1 sampler performs filter cassette, single and multiple sorbent tube sampling with constant flow accuracy, while offering convenient programmable timing options.

The Sensidyne Gilian GilAir pumps (GilAir-3 & GilAir-5) have one of the largest user bases of any air sampling pump worldwide. These reliable 3 and 5 liter per minute air sampling pumps have automatic constant flow assuring sampling is maintained within +/- 5% of the initial set point. Setting the flow rate on the GilAir-3 & GilAir-5 is a simple process that requires no special adjustment tool so you spend less time configuring pumps.

The Gilian  GilAir-5 is now available with nickel-metal hydride (NiMH) batteries that virtually eliminate memory effects and lazy battery issues. NiMH batteries are environmentally friendly, recyclable and do not pose a risk to the environment when being disposed. New NiMH battery packs are backwards compatible with  GilAir-5 pumps that currently use NiCd batteries and are user replaceable by removing only two screws on the rear of the pump.

GilAir-5 Hazardous Approval Ratings:
Intrinsic Safety
UL Class 1, Div 1, Groups A, B, C, D; Class 2, E, F, G; Class 3
EMC: Emissions Standards
EN 55011:2009/A1:2010 Group 1, ClassA
ICES-003 - Issue 2 Class A
FCC PArt 15 (per ANSI C63.4:2015) Class A Verification
EMI: Immunity Standards
EN 61326-1:2013;
IEC 61000-4-2:2006 / EN 61000-4-2:2009;
IEC 61000-4-3:2006 / EN 61000-4-3:2006/A1:2008/A2:2010

Part no: 800883-171-1205 - GilAir-5 R Pump, 5-Pack with Universal 5-Unit Charger, 120V, Basic, NiMH

Specifications

  • Dimensions: 4.1" x 3.1" x 2"
  • Weight:  22 oz.
  • Battery Pack:  6 volt, 1.8 amp hour
  • Battery Type: Rechargeable Nickel-cadmium or Nickel-metal-hydride
  • Battery Charge Time:  14-18 hours
  • Constant High Flow Range: 850-5000 cc/min
  • Operating Temperature Range: 32 to 104 degree F
More Information
Brand Sensidyne LP
Dimensions 4.1" x 3.1" x 2"
Air Filtration Tool Type Air Sampling Pump
Battery Pack 6 volt, 1.8 amp hour
Constant High Flow Range 850-5000 cc/min
Operating Temp Range 32 to 104 degree F
Flow Rate 1-5000 cc/min

Setting/ Verifying Flow Rate

Equipment Set-Up

  1. Use a GilAir-5 pump with a fully charged battery pack.
  2. Attach tubing to the pump.
  3. Connect the collection device to the tubing.
  4. Connect the tubing from the collection media to a Gilibrator 2.
  5. Setup and turn on the Gilibrator 2.

Field Calibration/Flow Verification

Field calibration (flow rate verification) must be performed before sampling and when setting the flow rate.

For Basic models skip to Step 4. Pump should be off.

  1. Use a small Phillips screwdriver to loosen the side anti-tamper plate screw.
  2. Rotate the side cover plate 180°.
  3. Use a pointed instrument such as a ball-point pen or paper clip bent 90° to press the MODE/HOLD button twice. CAL should appear on the display. CAL allows you to run the pump without actually collecting run data. 3A = Clock model. 3B = Program model.
  4. Use a small Phillips screwdriver to loosen the front anti-tamper plate screw.
  5. Rotate the front cover plate 180°.
  6. Move On/Off switch to the On position.
  7. Make sure the Gilibrator 2 is on and working.
  8. Set the pump flow rate by turning the flow adjust screw. (Clockwise for increased flow and counterclockwise for decreased flow. Use built-in rotameter only as a flow indicator. Use the Gilibrator 2 for actual calibration measurements.
  9. When desired flow rate has been reached, turn off pump and Gilibrator 2. The pump is now ready for sampling.

Taking a Sample

Note for Basic Models:

Start and stop times must be recorded to determine sample time.

  1. Move the On/Off switch to the On position.
  2. Place the pump, tubing and cassette on your person.
  3. When sampling is completed, move the On/Off switch to the Off position. Record sample data.

Battery Maintenance

The  GilAir-5 air sampling pump uses rechargeable Nickel-Cadmium or Nickel-Metal-Hydride batteries that must be fully charged and properly maintained to achieve maximum pump run time. The battery pack may be charged separately or while installed on the pump.

Battery packs are charged through a built-in jack, on the side of the battery pack. Note: The charging plug is polarized to prevent improper insertion.

CAUTION:  Do not short the battery terminals or the charging jack. Shorting will result in irreversible damage to the battery pack.

Filter Maintenance

The inlet filter should be changed after six months of regular use or whenever the outer portion of the filter becomes discolored. The filter center retains its original color as a reference.

  1. Unscrew and remove the four filter housing screws .
  2. Remove the filter housing.
  3. Remove the large filter o-ring.
  4. Remove the filter. Make certain the small center o-ring is properly seated inside the pump.
  5. Place the new filter inside the filter housing, followed by the filter o-ring .
  6. Install the filter housing in the pump and secure with the four housing screws.

 

 

Attachments

Write Your Own Review
Write a ReviewGilian GilAir-5 Air Sampling Pump 5 Pack Kit
To Top