Novatek's Novair 1000 Negative Air Machine

Rating:
100 % of 100
$1,125.00
In stock
SKU
AM0104

The Novatek Novair 1000 Negative Air Machine w/ HEPA is perfect for use in abatement, hospitals, air scrubbing, or anywhere dust is concern.

The Novair 1000 Portable Air Filtration for use in abatement, hospitals, air scrubbing, or anywhere dust is concern. Available in a variety of power sources (110v-220v 50/60Hz) and filter configurations.

Features

  • True 1000 cubic feet per minute air movement with all filters in place.
  • Powerful 1.00 Hp motor
  • 110v 60Hz
  • Vertical configuration
  • Utilizes standard 16x16x11.5 HEPA filters or nuisance dust filters
  • Polyethylene shell is seamless and dent proof
  • 2 speed motor
  • Hand truck configuration featuring no marring skids and wheels allows for easy transport by one operator. Compact upright design is perfect for tight spaces .

Benefits

  • Smooth, consistent air flow
  • Power motor pulls particulate deeper into the media extending filter life
  • Small footprint-Perfect for tighter areas
  • Replacement filters readily available
  • Filters for hazardous material or nuisance dust
  • Dent proof, leak proof polyethylene. Lightweight and virtually indestructible
  • Easy to clean and decontaminate

Specifications

  • Model: Novair 1000 c/ w HEPA
  • Part #: F1000
  • Weight: 94 lbs. (42 kg)
  • Dimensions: 20" x 23" x 40" (51 x 58 x 102cm)
  • Motor High/ Low: 1hp - Two Speed, Thermally Protected.
  • Air Volume: 1000 - 500 cfm 1700 - 850 m3/ hr
  • Power: 115V 5amp, 60hz
  • Filters: HEPA Filter, 1/2" Pad, Ring Filter
More Information
Brand Novatek
Dimensions 20" x 23" x 40"
Air Filtration Tool Type Negative Air Machine
Motor 1 Hp
Air Volume 1000 - 500 cfm 1700 - 850 m3/ hr
Current 15 Amp
Voltage 115V
Frequency 60hz
Filtration HEPA Filter, 1/2" Pad, Ring Filter
Equipment Features With HEPA
Write Your Own Review
Write a ReviewNovatek's Novair 1000 Negative Air Machine

Prior to Use

  1. Remove any excess dust/dirt from exterior housing and control panel.
  2. Be sure the HEPA Filter and Pre-Filters are installed properly with a positive seal.
  3. Insure the unit is connected to a dedicated 10Amp, 110/115 volt circuit.
  4. Make sure unit is safely positioned as not to impede any entrances or exits of the work area.
  5. If applicable, check exhaust port connections for tight seal.

Caution: Insure your power cord is securely attached to the male recessed plug. If any movement or play is detected, change power cord immediately! If connection remains loose, immediately replace the male recessed plug.

Operation

  1. When utilized in containment, the Novair should be positioned a minimum distance away from the entrance and located towards the center of the containment.
  2. When using a HEPA filter, insure the filter is correctly installed and sealed. Anchor and secure the filter utilizing the supplied retaining brackets.
  3. Install the Ring Filter and Pre-Filter pad into unit.
  4. Insert the female end of your 10 amp rated, UL listed cord, into the male recessed plug on control panel.
  5. To begin operation, depress the power switch to either the low or high position. Locate the differential pressure gauge located on the control panel. The gauge will register between 1.0” – 1.2” of water column. This is the initial reading when filters are new and unused. This reading will incrementally increase as filters become loaded with dust and debris. When the gauge reaches 1.6” – 1.8” of water column; either one or all of the filters are loaded and in need of replacement.
  6. Pressing the power switch to the left will operate the unit in “Low” mode equivalent to 500 CFM.
  7. Pressing the power switch to the right will operate the unit in “High” mode equivalent to 1000 CFM.

Safety

Novatek Negative Air Machines are highly efficient systems designed to reduce air borne particulates. To insure proper operation, the following safety precautions should be strictly adhered to:

  1. Do not leave machine unattended when connected to a power source. Turn OFF electric supply and disconnect from power source when not in use and/or before servicing.
  2. Do not operate with damaged or malfunctioning parts. If the unit is not working as intended, return to an Authorized Repair and Service Center.
    • NOTE: Always replace worn or damaged components with genuine NOVATEK parts. Failure to comply could result in equipment failure and will void warranty.
  3. Remove any loose clothing and adornments prior to operation.
  4. Keep outer surfaces free of dirt and debris. Be sure all controls clean and functioning properly.
  5. Turn off power prior to any filter inspection and replacement.
  6. Do not operate unit with flammable or combustible liquids or gases present.
  7. Do not operate the machine in wet conditions. Failure to do so could result in electrical shock or death.
  8. Never operate the unit if there is any possibility of contact with the blower wheel.
  9. It is the responsibility of the unit owner to ensure that all equipment is maintained in safe and efficient operating condition.
  10. Stacking of machines is limited to three units. Do not house stacked machines in areas hotter than 100 degrees Fahrenheit. (Failure to comply will void warranty.)

Attachments

To Top