Give Us A Call: (800) 872-3684

Omniguard Cellular Pressure Recorder

$1,749.99
In stock
Only 2 left
SKU
AS0055

The Omniguard Cellular in a completely self-contained package, is designed to be the most reliable long term monitoring recorder in the field.

The Omniguard is the clear choice for monitoring and documenting Vacuum and Pressure in a containment area. Ideal for Asbestos, Lead and Mold abatement, and Clean Room monitoring. The Omniguard utilizes state of the art pressure measurement technology to accurately monitor pressure inside a containment area.

We've taken everything we've learned from over 25 years of making pressure monitors and put it into the Omniguard. The same great ease of use, accuracy, versatility and reliability you've come to expect from a product bearing the Omniguard name, with the new features you've asked for.

With a touch screen interface, set up and navigation of the Omniguard has never been easier. The 4.3" Color LCD is much larger than the previous screen and now also has color indicators bordering the LCD screen make it easy to see the status of the monitor even from a distance.

The touch screen navigation has greatly simplified the set up and usage of the Omniguard. The user-friendly interface makes it easy to move from menu to menu and quickly access the information you need.

The Omniguard now offers 4MB of logs space, which will hold 6+ months of normal job logs. That's 8x more than the previous version of the Omniguard. You can also access and download specific job logs with ease. You no longer have to download all the job logs on the Omniguard. Plug in your USB flash drive to pick and choose specific days/weeks/or whole job logs to download.

You never need to worry about a short loss of power disrupting your ongoing job log. With a built in Lithium Ion battery, the Omniguard now supports up to 6 hours of operation without AC power.

Now with an international power supply that operates from 80-240VAC, 50-60Hz, the Omniguard can operate around the world with no modifications. The Omniguard is now multi-lingual; easily switch between English, French, or Spanish.

We continue to offer the functional self-contained design so there are no AC adapters to lose or hoses to keep track of. Everything fits inside the case so you can protect your investment from damage by operating the Omniguard with the lid closed.

The Dual USB ports continues to make collecting and viewing your job logs quick and easy. You can download and view logs using your computer's USB port and our free software. And you can now monitor the current status and change the setup directly on your PC. If you are on site you download job logs directly to a USB flash drive at the job site. You can view and store the logs later on your PC.

The latest Omniguard adds built in wireless remote monitoring using cell service or WiFi. If you jobs require 24/7 coverage or you just want to know what's happening on the site day to day, you can now get real time email reports when the status of your Omniguard changes. You'll also have the option of receiving a job log of the last 24 hours once a day. And mobile app is available so you can see the latest updates without signing up for emails from each of your job sites.

With features designed to display information clearly and quickly, you'll be confident that you have the best instrument for the job.

  • Built in cell modem and WiFi gives you 24/7 remote monitoring of your job site automatically.
  • Select which status updates you want to receive via email; power change, waiting for pressure, alarm or normal operation.
  • Email job log once per day at selected time.
  • Enter up to four different email addresses to receive status updates, job logs or both.
  • Free cell service for the first two years.

Features

  • Real time monitoring of differential pressure and/or vacuum level
  • Dual inlet ports allow monitoring between two areas
  • Programmable high and low alarm setpoints
  • Extremely simple to set up and use with 4.3" Color LCD touch screen interface
  • Pressure displayed in Inches WC, Millimeters WC or Pascals
  • 4MB of log space holds 6+ months of normal job logs
  • Built-in Lithium Ion battery supports portable operation up to 6 hours without AC power.(Printing is automatically disabled when operating from battery to conserve power.)
  • 95 decibel audible alarm notifies workers and bystanders when containment is lost
  • USB Type-A port lets you save logs directly to a flash drive
  • Second USB port supports PC communication for transferring job logs, real time monitoring and configuration editing
  • Thermal printer, no ink ribbons
  • Printing in any position with paper contained in a protected compartment
  • Multilingual - English, French and Spanish.
  • Instant on screen help
  • Multiple reports available at the touch of a key
  • Print/log interval adjustable to conserve paper and memory
  • Variable response rate to avoid nuisance alarms in windy environments
  • Passcode protection prevents tampering
  • Automatic printout and logging of all settings changes
  • Configuration report prints current settings and monitoring status for easy review
  • View log on screen, scroll through entire memory contents
  • International power supply operation, 80-240VAC 50-60Hz.
  • Rugged self-contained unit includes power cord, owner's manual, 10' of hose and spare paper roll stored in the case

Specifications

  • Operating Pressure Range: +/- 0.250 inches Water Column ( +/- 6.35 mm WC, +/- 62.5 Pascals)
  • Accuracy: +/- 0.003 inches Water Column or +/- 1% of reading whichever is greater
  • Resolution: 0.001 inches Water Column ( +/- 0.05 mm WC, +/- 0.5 Pascals)
  • Burst Pressure: 3 psi (20 kPa) on either inlet nozzle
  • Pressure Units:  "WC (inches Water Column), mmWC (millimeters Water Column) or Pa (Pascals)
  • Data (Log) Storage: 4 MB non-volatile memory
  • Display: 4.3" Color Touchscreen LCD (480 x 272 pixels)
  • Internal Clock: The internal clock is powered by a self-charging lithium-ion battery that provides clock operation when AC power is not present
  • Printer: 20 character wide thermal printer (uses 2.2" wide thermal printer paper)
  • Pressure Reading Log Rates (Log Rate):Normal Operation -- Highest and lowest pressure readings are logged & printed at intervals of 5, 15, 30 minutes or OFF
    Alarm Condition -- Highest and lowest pressure readings are logged & printed at intervals of 15, 30, 60 or 120 seconds for first 10 minutes of alarm condition, increasing to 15 minute intervals thereafter
  • Alarms: Two programmable alarm settings, 95db audible alarm and red bordered on-screen warning indicate alarm condition
  • Cellular Service:  Cellular modem can email status changes up to four times per hour and the jog log of the last 24 hours once a day. First two years are free. Service is provide by Verizon and is only available in areas with Verizon coverage in the USA.
  • Pressure Inlet Nozzles: Two 3/16" OD barbed hose connectors, 10 ft of pressure hose provided
  • USB Port: USB V1.1 Type-A
  • USB Port: USB V1.1 Type-B
  • AC Power: 80-240 VAC 50-60Hz 10W (with 6 ft power cord)
  • Battery Power: Internal rechargeable 3.7 Volt Li-ion type battery provides 4-6 hours of portable operation, recharges in 4 hours when AC power is available (printer is disabled when powered by battery)
  • Operating Temperature Range: 32°F to 104°F (0°C to 40°C)
  • Case: Dimensions 9.25" x 7.5" x 4.5", Shipping Weight 8 lbs., case & handle is copolymer polypropylene with polycarbonate window in the lid, and stainless steel hanging hook
  • Warranty:  One Year Limited Warranty

 

More Information
Brand Sensidyne LP
Dimensions 9.25" x 7.5" x 4.5"
Air Filtration Tool Type Cellular Pressure Recorder
Battery Type Rechargeable 3.7 Volt Li-ion
Accuracy +/- 0.003 inches Water Column
Burst Pressure 3 psi
Alarms Two programmable alarm settings
USB Port USB V1.1 Type-A & Type-B
Watts 10 Watts
Operating Range +/- 0.250 inches Water Column

Work Area Setup

The Omniguard should be placed on a solid (non-vibrating) surface, excessive vibrations disrupt accurate pressure measurement.

  1. The intake end of the pressure tubing must be located a minimum of 5 feet away from any openings or HEPA fan/filter units. Choose
    a location away from excessive dust or moisture.
  2. Cut a 1/2” slit in the polyethylene barrier and feed approximately 1 ft. of pressure tubing through it. Tape the tubing securely to the
    polyethylene.
  3. Connect the free end of the tubing securely over the nozzle. Be careful not to turn the nozzle.
  4. Route the tubing and AC cord through the foam notch area on the upper right corner of the case. Close the lid to protect the Omniguard from damage, (be careful to not pinch the tubing or AC cord).
  5. The maximum hose length is limited to 70 ft (for 3/16”ID hose). Lengths beyond 70 ft can degrade reading accuracy.

Caution: It is important that there be no kinks or sharp bends in any part of the tubing. Any blockage could inhibit accurate recording of the pressure in the
containment area.

Power-Up

To use the Omniguard, plug the power cord into a standard wall outlet providing 115-230 VAC, 50-60 Hz and press the power button. The first time that a new Omniguard is turned on, the settings will be at default values.

Attachments

Write Your Own Review
Write a ReviewOmniguard Cellular Pressure Recorder
To Top